All examsEPA 608Foundation path
View coverage
RECALL, THEN CHECK

EPA 608 Flashcards & Study Review

Read 12 sample cards from the 40-card EPA 608 foundation collection. Try recalling each answer before checking the explanation.

Version 2026-10-27 · Original foundation materials · No sign-up

What this collection covers

Selected Core and Type I/II/III written-knowledge foundations.

The cards preview selected ideas; they do not measure readiness for the whole examination. Your personal review schedule is available in the review tool.

Author-reviewed learning materials. Independent educator review is pending; question difficulty has not been calibrated with learner results. Check coverage and gaps before planning your preparation.

Sample flashcards, with answers

CARD 01 · Core

A technician will service a factory-sealed household freezer containing 4 lb of refrigerant. Which certification category directly covers this small appliance?

Answer & explanation

Type I. Classify the appliance before selecting a certification.

Learn: Certification and appliance boundaries
CARD 02 · Type I

A factory-sealed window air conditioner contains 3 lb. Which charge band applies to the small-appliance recovery decision?

Answer & explanation

Five pounds or fewer. A small appliance is fully manufactured, charged and hermetically sealed in a factory with five pounds or less of refrigerant.

Learn: Recognizing small appliances
CARD 03 · Type II

A high-pressure stationary appliance has a full charge of 50 lb. Recovery equipment was manufactured after November 15, 1993. In EPA's general service evacuation table, which target applies?

Answer & explanation

0 inches Hg vacuum. The appliance is high-pressure and its full charge is less than 200 lb.

Learn: High- and medium-pressure evacuation
CARD 04 · Type III

A low-pressure chiller is opened for service under the general evacuation rule. What listed absolute-pressure target applies?

Answer & explanation

25 mm Hg absolute. EPA lists 25 mm Hg absolute for the general low-pressure appliance evacuation target, in both recovery-equipment date columns..

Learn: Low-pressure evacuation and units
CARD 05 · Core

Recovered refrigerant from one supermarket rack is proposed for another rack owned by the same company. Which ownership fact supports reuse without mandatory ownership-transfer reclamation?

Answer & explanation

Both appliances have the same owner. Recovered refrigerant may be returned to equipment under the same ownership; transfer to another owner requires reclamation by an EPA-certified reclaimer..

Learn: Venting, recovery and ownership
CARD 06 · Type I

A qualifying small appliance initially contains 2 lb. Recovery equipment was manufactured before November 15, 1993, and the appliance compressor is functional. Using the percentage method, what minimum mass must be recovered?

Answer & explanation

1.6 lb. The applicable recovery fraction is 80%; multiply 2 lb by 80/100.

Learn: Small-appliance recovery decisions
CARD 07 · Type II

An appliance normally contains 100 lb of ozone-depleting refrigerant and is used for comfort cooling. Which annual trigger rate belongs to that category?

Answer & explanation

10%. The stated ODS appliance contains 100 lb, so it meets the 50 lb size condition.

Learn: ODS leak-repair triggers
CARD 08 · Type III

A low-pressure appliance qualifies for the limited non-major repair exception. What pressure condition is stated before opening?

Answer & explanation

Pressurize it to 0 psig. For the limited non-major low-pressure repair exception not followed by evacuation to the environment, pressurize to 0 psig before opening; prohibited subsequent-purge methods are not generally allowed..

Learn: Low-pressure repair planning
CARD 09 · Core

A certified technician is asked where EPA requires certification evidence to be kept. Which answer fits?

Answer & explanation

At the place of business. Technicians keep certification evidence at the business through three years after ceasing technician operations; EPA does not generally require carrying the card at every service call..

Learn: Evidence and certification records
CARD 10 · Type I

A scrap processor receives a refrigerator still containing refrigerant. What must occur before final disposal?

Answer & explanation

Refrigerant recovery under the applicable requirements. The final person in the disposal chain must ensure refrigerant recovery before final disposal; a documented prior recovery can satisfy the chain requirement..

Learn: Following the disposal chain
CARD 11 · Type II

A stated non-major high-pressure repair will not be followed by evacuation to the environment. What pressure is required before opening under this limited exception?

Answer & explanation

0 psig. The limited exception for a non-major repair not followed by evacuation to the environment requires high- or very-high-pressure equipment to reach 0 psig before opening..

Learn: Service exceptions and oil
CARD 12 · Type III

An applicable ODS chiller is recharged after service. Which quantity belongs on the customer's service documentation?

Answer & explanation

The amount of refrigerant added. For covered large ODS appliances, the customer receives refrigerant-added records and required inspection/verification documentation with dates, methods, locations andresults..

Learn: Chiller records and lifecycle decisions

Use the cards as a recall routine

  1. Read the prompt and explain your answer before looking below it.
  2. Compare your reasoning with the saved answer, then revisit the linked lesson if a distinction is unclear.
  3. Use the spaced-review tool to schedule another attempt; its personal state stays in your browser.

Sources and preparation route

These prompts and explanations are the site's original learning materials. The reference links below support the selected skills; they are not endorsements or official examination questions.